0000003405 00000 n 0000001739 00000 n If you are a contractor, you will need bring a copy of your contractors license and proof of workmans compensation insurance. 2) Layout a typical system on your plat map and see if your system meets the required setbacks of Table 302.1 (illustrated in Figure 2). MINIMUM LOT SIZE RULES 10 CMR 243 (August 1, 2005) Page 1 of 8 CHAPTER 243 MINIMUM LOT SIZE RULES SUMMARY: These rules describe the requirements for minimum lot sizes and for waivers to the Minimum Lot Size Law, 12 MRSA 4807. 2022 BuildingAdvisor.com;All rights reserved. 0000001599 00000 n Minimum Requirements for Lot and Building Size Although minimum lot or building size requirements have fallen out of favor over the past several decades, variations on this theme were still fairly common in local codes of the 1950s. 0000003029 00000 n If they hire a contractor, the contractor is considered a "prime" and required to be licensed, as well as, obtain the building permit for inspections. <]>> If you are at an office or shared network, you can ask the network administrator to run a scan across the network looking for misconfigured or infected devices. May 8, 2018 at 9:21 pm. from the minimum lot size requirements. endstream endobj startxref The department reported the results of the rule review and made recommendations to the State Board of Health (Board) to begin rule making. 68-221-401). Some examples of major changes are replacing a sewage tank, and replacing or expanding an absorption field. For Sale: Lot 70 Ridgecrest Rd, New Tazewell, TN 37825 $25,000 MLS# 1215923 Lone Mountain Shores is a Community on Norris Lake in Claiborne County, Tennessee, offering, marina, boat ramp, It . 0000001325 00000 n %PDF-1.5 % 0000017709 00000 n 0000002918 00000 n Septic System Construction Permit Who Needs One? 0000018423 00000 n Cheatham County, Tennessee Government 0000000696 00000 n 0000016887 00000 n trailer << /Size 91 /Info 51 0 R /Root 54 0 R /Prev 85885 /ID[<5ac0df4413bfc163b434df09870908be><24e0518a321b0ece5774bfcd21006588>] >> startxref 0 %%EOF 54 0 obj << /Type /Catalog /Pages 49 0 R /Metadata 52 0 R >> endobj 89 0 obj << /S 294 /Filter /FlateDecode /Length 90 0 R >> stream 68-221-401. %%EOF The Policy Subcommittee met on February 21 and March 14 and the Technical Subcommittee met on April 4 to develop recommendations. Replacing Failed Drain Field in Same Location. Onsite Wastewater Treatment and Disposal Systems-Design Manual (pdf) (8.79 MB) Provides technical information on onsite wastewater treatment and disposal systems for those who design, construct, operate, and maintain wastewater systems. Completing the CAPTCHA proves you are a human and gives you temporary access to the web property. 0000005347 00000 n The department then completed an informal comment period in August to October in 2019. This meeting provided the committee an opportunity to review the revisions to the proposed language based on informal comments and feedback from local health jurisdictions. The Geologist or Civil Engineer doing the testing will issue a final determination on this. In addition, the contracts should not be split into phases to circumvent the law. 604KB. 13941 0 obj <>stream %PDF-1.3 D. Those tracts, parcels, industrial or commercial developments which have received one or more of the approvals listed in B.1., above, on or prior to September 7, 1989 are exempt from minimum lot size requirements for use of septic tank-subsurface disposal systems. General requirements. 0000005958 00000 n New home, additions, manufactured, modular 60 cents / square foot University of Tennessee Agriculture Extension. buildingadvisor says. 0000002112 00000 n 0000004511 00000 n A septic tank should not be considered if the lot size is under 15,000 square feet. -m@:&{M:4 The Technical Subcommittee met on July 26 and August 16 and the Policy Subcommittee met on August 2 and August 23 to develop recommendations. from the minimum lot size requirements. Division of Ground Water Protection regulates subsurface 13920 0 obj <> endobj This applies to lots receiving . << /Length 5 0 R /Filter /FlateDecode >> Regulations that govern septic systems are found in the Division's Chapter 1200, 1- 6, and include. An 1100 sf two-story house needs about 600 sf of land. 0000009505 00000 n Any complaints relating to the possible health risks of a septic tank should be forwarded to an If you are a property owner pulling your own permit you will need a completed permit application and proof of ownership. 0000007005 00000 n The seventh full committee meeting was held in Kent on August 8. This applies to lots receiving approval or created rSeptembe7,1989. In early 2020, we strategically paused work on the rule revision to allow ourselves and our local health partners to respond to the COVID-19 pandemic. 0000007183 00000 n 0000004082 00000 n The committee reviewed recommendations from the Policy and Technical Subcommittees for changes to the rule regarding designs which facilitate operation and maintenance, inspections, minimum lot size and land area requirements, repair of failures, setbacks to stormwater facilities, sewage products, proprietary product bacterial reduction testing and field verification, abandonment, remediation, residential sewage quality, sea level rise in local management plans, the definition of fill and protection zone, other miscellaneous definitions, updates, and changes for clarity. 1200-1-6-.07 Septic Tank Capacity 1200-1-6-.18 Installer of Subsurface Sewage Disposal Systems 1200-1-6-.08 Design of Septic Tanks 1200-1- 6-.19 Septic Tank Pumping Contractor . xref Combining Foam & Fiber Insulation in Cathedral Ceiling (Flash & Batt). 0000004095 00000 n Department staff also asked committee members to decide with which of two subcommittees they want to participate. The Policy Subcommittee met on June 6 and the Technical Subcommittee met on May 2, 9, 30 and June 20 to develop recommendations. 0000004007 00000 n Apply for a Permit | Report a Code Violation | Building Permits | Adopted Codes | Flood Hazard Areas | Property Maintenance Standards | Fees | Forms & Applications | Land Use & Zoning | Employment Opportunities | Frequently Asked Questions, Permit Fees Wastewater Ordinance Map. 0000004250 00000 n DEC's website. The private roads are perfect for hiking or biking to any of the community parks . This two-plus acre, gently sloping wooded Lot on Norris Lake offers primary channel year-round water and is dockable. bcku]ya@66HzvgB?+z1,2NY\TKd71H>#^07Hh/L[MQWe Any accessory use or building located on a lot under this section shall conform with provisions of this resolution as related to use and dimensional . (Q) What is th e minimu m lot size requ irement for in stalling a sep tic system on my property? You must obtain a subsurface sewage disposal system permit (septic permit) which will enable you to know you have proper soils. 238 0 obj <> endobj View theRule Revision Timeline (PDF). i7l@Je00` U+I eU @, Variances - Hearings - Finality of decision. The committee reviewed recommendations from the subcommittees for changes to the rule regarding property transfer inspections, connections to sewer, minimum septic tank sizing, setbacks to stormwater treatment systems, and pump chamber sizing. 0400-48-01-.08 Septic Tank Capacity 0400-48-01-.22 Domestic Septage Disposal 0400-48-01-.09 Design of Septic Tanks 0400-48-01-.23 Maintenance Provider for Advanced 0400-48-01-.10 Effluent Treatment Devices / Systems Treatment Systems and Subsurface Drip 0400-48-01-.11 Location of Septic Tanks, Dosing Disposal Systems We are currently preparing the rule and related analysis for filing and will provide an update the State Board of Health in January 2023 and anticipate filing the proposed rules in March 2023. About APA Join Log In Cart Toggle navigation Menu Toggle Search Search by keywordSearch Membership trailer the 31 December of the year it was issued. 0000001989 00000 n 1. d1L4X jX"&HRd^ Kbd7dSPxp--!-Q,!8AH2e0et000 Reply. 0000002995 00000 n Q: What's the minimum lot size for a septic system? Once a permit is granted, it is only valid until These standards became effective January 1996. 0000009303 00000 n Rules for Waivers to the Minimum Lot Size Law (CMR 243). *J^w K)*s5ozf565z/y{Wm}||7;j|[U}nn7?&G ty]SC#fcD6O>:6;DYW(|I3,n7WM_`]uN&1,h#NM9o=:U-bq%dPvsFs]xh^ZmM~V|U='z5>l 2V[Eh}##zsu SkHUwJk7xF _VMwOb-kv2S9a e 0000008920 00000 n Within any agricultural or residential districts, accessory structures will be permitted on lots with a minimum of fifteen (15) acres prior to the construction of a principal building on the lot. ?6p-Kg$\C@( j,\dV9:neZN|W5wFdp 0 Remodel, accessory structures . 30 cents / square foot Department. leu+k_s>" - Oq5#|8?,0WL`\:$7%Y*#%my2cD4LQ+ SWcGM=R)!yV4)INirM"=uv&_jPahLL5$TZmfe+;F:Q startxref Although the Washington lot sizes were based on . Environment and Conservation. 0000006573 00000 n 0000004863 00000 n HMo@sz Stakeholders approved the charter and reviewed the list of issues and issue paper. Designs Which Facilitate Operation and Maintenance Final (PDF), Proprietary Product Field Testing -110-120-130 (PDF), Proprietary Product Field Testing Table 6 and 9 (PDF). 0000003458 00000 n 0000001518 00000 n startxref xref Department of Health staff presented a review of the history of on-site regulations in Washington, presented and asked for comment on the charter, and provided a list of issues to be considered for revision and an example of an issue paper for the stakeholder committee to review. Environmental Field Office. Adequate facilities .10 cents / square foot. xA 04d\GczC. created to implement programs that help preserve the state's environmental resources. The committee reviewed recommendations from the Policy and Technical Subcommittees for changes to the rule regarding horizontal separations, waivers, service provider licensing, inspections, technical advisory group, policy advisory group, and the definitions of on-site sewage system, repair, expansion, adjacent to marine installations, residential sewage, black water, floodway, daily use, grease trap, low flow waste, surface water, drainage areas, prohibited waste types, and failure. Grading permit .. $50.00 0000002692 00000 n 0000007261 00000 n Please enable Cookies and reload the page. 0000002675 00000 n Accessory dwellings, pole barns, and agriculture buildings that contain areas for human habitation must be certified by a licensed architect or engineer that compliance with the International Residential Code has been met for the entire structure. 0000004699 00000 n Priority issues included local management plans, property sale inspections, treatment levels, ultraviolet disinfection, and licensing of operations and maintenance providers. -Two residences can discharge into one liquid waste system provided lot size requirements are met and the system is designed accordingly. 0000016232 00000 n Pre- fabricated open car ports .$15.00 Meeting Agenda - September 13, 2018 (PDF), Increase Septic Tank Sizing When Low-Flow Fixtures Used (PDF), On-site Sewage System Setbacks to Stormwater Treatment Systems (PDF). This meeting provided the committee an opportunity to review the revisions to the proposed language based on informal comments and feedback from local health jurisdictions. Chapter 0400-48-01 - Courtesy of the Secretary of State's Office, This Page Last Updated: January 19, 2023 at 3:41 PM, Septic Installer, Pumper and Land Disposal Permits, Online Application for Septic Related Services, Regulations to Govern Subsurface Sewage Disposal Systems, Licensed Septic System Installers & Septic Tank Pumpers, Tennessee Code : Title 68 Health, Safety and Environmental Protection: Chapter 221 Water and Sewerage: Part 4 Subsurface Sewage Disposal Systems. 0 0000006552 00000 n 0000007894 00000 n 0000003426 00000 n 68-221-401) Includes the following: 68-221-401. 13934 0 obj <>/Filter/FlateDecode/ID[<5015E27E23802C4BBB2464D8AD6618D2>]/Index[13920 22]/Info 13919 0 R/Length 75/Prev 669810/Root 13921 0 R/Size 13942/Type/XRef/W[1 2 1]>>stream The private wooded lot is set up for short term R/V use and camping, with a 3 bedroom septic system, electricity, wood platform and fire pit. Regulations to Govern Subsurface Sewage Disposal Systems Tennessee Code : Title 68 Health, Safety and Environmental Protection: Chapter 221 Water and Sewerage: Part 4 Subsurface Sewage Disposal Systems (NOTE: For best results, click on the above link and do a LexisNexis search for T.C.A. In late 2017, Department of Health (department) conducted a review ofChapter 246-272A WAC, On-site Sewage Systemsto determine the chapter's overall effectiveness and areas needing revision. septic tank systems was found to be a function of potential leaching field failure, groundwater contamination, The Board may consider other technical and editorial changes as needed. The zoning of a property can be verified by applying the zoning layer as found on the zoning map. If a drinking water system is on the property, the minimum lot size for a septic tank consideration is 20,000 square feet provided percolation is satisfactory. The full committee will develop recommendations to the department on these issues. %PDF-1.4 % The rules for septic systems are different in every state in the US and often differ from one town or county to the next. Regardless of whether you are a contractor or homeowner, to install a septic system, you must have a construction This lot is in the Lone Mountain Shores. OCGA 31-3-5 (b) (2) to establish minimum lot sizes. 0000002701 00000 n stream Public Sewer Restriction If there is a public sewage system available to be tied into, then the State of Tennessee will not issue a permit for a septic system. 0000007204 00000 n 0000008031 00000 n 0000016253 00000 n The full committee developed recommendations to the Department of Health on these issues. 0000001107 00000 n The third full committee meeting was held in Kent on November 8. B. hb```y,W((EJ.JS\MM6/n*){yB/Yg|,|Zkt__>]7M9qoS'^mc+)Bv7Gby9Lyo;sVX_&kcC:Tbeb@@bVD\M@nW@lfq5@!+EYI@dAbb!`b Get email alerts based on your topic preferences like news releases, job openings, emergency updates and more! NlECK#)-&YZ6=fM r F)AMF,f}B?80 rA"`aqZk(b!T#ku3F8MYD(%L)+n:zk7bj6cjY5 VVfF~WzB{~WoDQE :a=EkhM~e+hSKhsr_,UUki]>B4eTwpsU5(XeGkux/Wmvz:hyZ5l2^mxvpM You will receive a copy of your septic permit which must be presented to us prior to issuance of a building permit. <<7EE6DF283D744641AEA459EBE30DD108>]>> Mobile home (single wide) permit fee.$250.00 Mississippi State Department of Health 570 East Woodrow Wilson Dr Jackson, MS 39216 866-HLTHY4U Contact and information. The requirement that your septic system must be at least 100 ft. away from any wells (your own or your neighbors) was particularly difficult to meet on small lots. Penalty fine / building with out a permit.Double permit fee, Impact Fees 0000009098 00000 n 0000017688 00000 n The eighth full committee meeting was held in Tumwater on December 12. 0000006465 00000 n (4) Individual sewer connections. In late 2017, Department of Health (department) conducted a review of Chapter 246-272A WAC, On-site Sewage Systems to determine the chapter's overall effectiveness and areas needing revision. (A) The minimum lot size for land subdivided, plated, recorded after January 1, 1988 and severed by a public water supply but utilizing individual on-site sewage disposal methods, shall provide a minimum of one acre. The first draft version of the revised rule and other committee materials are available at the bottom of the page. contact| Designs Which Facilitate Operation and Maintenance (PDF), Local Management Plans - Draft Rule Language (PDF), Local Management Plans - Draft Rule Language with Visible Edits (PDF). this in mind, the Department of Environment and Conservation was These standards cover new systems and major changes to existing systems. There is no minimum lot size requirement to construct a home. The zoning must allow residential development. 500 gallons per acre or lots that do not meet minimum lot size, advanced/alternative systems that reduce Total Nitrogen (TN) per Section 603 may be approved. 257 0 obj<>stream %%EOF The committee reviewed recommendations from the Policy and Technical Subcommittees for changes to the rule regarding permit requirements, designs which facilitate operation and maintenance, owner responsibilities, repair of failures, minimum lot size and land area requirements, and nitrogen reducing technology testing requirements. Installing A New Septic System In Tennessee Regardless of whether you are a contractor or homeowner, to install a septic system, you must have a construction permit, which ranges in cost from $150 to $500 depending on the type of septic system you wish to install. The Department's ;L Bo G&cbU0">yrTg5O[BaXc0l-lEG{u $.001100b% ` 6c Septic permit must match plans as far as bedrooms. Within any agricultural or residential districts, accessory structures will be permitted on lots with a minimum of fifteen (15) acres prior to the construction of a principal building on the lot. least 70% on a written or oral test issued by the Department. Maintenance of On-Site Sewage Facilities (Septic Systems) Overview . Your email address will not be published. 0000001710 00000 n Compared to that, a mandatory minimum of 5000 sf is definitely large. The first accessory structure on a parcel of property is excluded from this requirement if the accessory structure does not exceed two hundred (200) square feet. alters or extends a subsurface sewage disposal system. Minimum lot size for properties developed with on-site sewage systems has changed little in Washington state since statewide on-site rules were first established in 1974. Draft Rule Without Changes Shown (clean version) (PDF), Subscribe to Wastewater Rules and Regulations Email Updates, Peter Beaton, Rule Coordinator, 360-236-4031, Jeremy Simmons, Wastewater Program Manager, 360-236-3346, First Draft Rule With Changes Shown (PDF), First Draft Rule Without Changes Shown (clean version) (PDF), Summary of First Draft Rule Changes and Comment Form (Word), First Draft Rule Revision Update Workshop Presentation (PDF), First Draft Rule Revision Update Workshop Webinar Version Presentation (PDF). Pool permits $25.00 0000008772 00000 n In addition, to obtain the license, the contractor must achieve a pass mark of at 238 20 Sign up for weekly public health updates by e-mail: +. xb```b``1a`f`` @Q19!N_4]@+\L"Vq)lq!3&TY+4yKEsLeKPHRA~IN}IE% ^ b)X2P The ninth full committee meeting was held in Tumwater on February 13. 0000002311 00000 n The kickoff meeting was held June 25 in Kent. How To File A Complaint privacy, Department of Environment and Conservation. Larger lot sizes may be required to meet the requirements of this Manual depending on the proposed development of the property. lD^.Mgl0,THrfdi"_)WZEkc-v5Y6=dtuEY= :B__ :8[LV]n0VpoF7MV)3O X\XrdE~=][@MATlj0~k~s{Xu\wpU#fh/au~DA4adka0X E. 0000008623 00000 n Code. Ana RWQCB to have a minimum lot size of a one-half acre per dwelling unit using a septic system. sewage disposal systems, also known as septic systems. 0000000016 00000 n 350 Frey Street | K+*P%L@/;#!$mQC`sRJ(e*OB;E_I**aDlQ:4z~ u+>FL uJS:m I9F O g3"PTjS-H"hA8Pb5PG3hyfUd)'\^Gv - fI& %4g%^$gh+(Li4x9!uYU)E>u. (615) 687-7000 - Environmentalist. Accessory structures must be out of the required front setback and at least five feet from any side or rear setback. 0 To view/print pdf documentation you will need Adobe Reader. We restarted work on the rule revision in late 2021 and have worked with local health partners to make revisions to the draft rule for implement ability. ( Division Septic System Assistance County Map) 0000005743 00000 n Rules in PDF Download OSSF rules in PDF format. Definitions A. 0000001180 00000 n The Onsite Wastewater Treatment and Disposal Systems Manual (pdf) (20.5 MB) 0000016908 00000 n IXic\6M$,`X4 JQ 35Q`j D4X4H @ @AX:X. The state of Tennessee is concerned about protecting and improving the quality of its land, air, and water. 870 0 obj <> endobj Call us at (800) 447-2827. 0000000016 00000 n Should I Acclimate Hardwood Flooring & Leave Expansion Gap? Tasks In addition to regulating subsurface sewage disposal systems, the department upon request performs bacteriological water analysis on . Lot means a part of a subdivision or a parcel of land intended for the building of a single house, building, or . xb```"h^1":RG>o0^Uca+j2k}rk<=?/EL>Of9yG7(yQie\;WtTChV#q&!_8,4}q54xgZNlllll. %PDF-1.2 % An official website of the State of Georgia. Application forms are available online. 0000003225 00000 n The Technical Subcommittee met on September 27 and October 18 and the Policy Subcommittee met on October 4 and November 1 to develop recommendations. Mobile homes are only allowed in the Agriculture Zoning district. Answer : There is no minimum lot size. 0000003244 00000 n 0000000569 00000 n Tennessee Code : Title 68 Health, Safety and Environmental Protection: Chapter 221 Water and Sewerage: Part 4 Subsurface Sewage Disposal Systems(NOTE: For best results, click on the above link and do a LexisNexis search for T.C.A. I'm wondering if there's a standard definition for what a "large" lot is. % If you are on a personal connection, like at home, you can run an anti-virus scan on your device to make sure it is not infected with malware. License applications forms are available from the %%EOF The full committee will develop recommendations to the Department of Health on these issues. View the report,Evaluation of the Effectiveness of Chapter 246-272A WAC (PDF). home| On-Site Rule Revision Committee (ORRC) Charter (PDF), Historical Overview of Onsite Regulations in WA Presentation (PDF), WAC 246-[/] Review for ORRC Presentation (PDF), Add Pump Chamber Sizing to OSS Rule (PDF), Increase Septic Tank Sizing When Low-Flow Fixtures Are Used (PDF). Property setbacks were also difficult to meet with drain fields. permit, which ranges in cost from $150 to $500 depending on the type of septic system you wish to install. The sixth full committee meeting was held in Kent on April 18. Manufactured and modular homes are allowed in any residential zoning district. 4 0 obj 0000002778 00000 n So zoning variances were often granted to allow for reduced clearances. A person who owns property is allowed one permit every two years to build their home as long as it is not for sale, lease or rent (individual use). Permitting for on-site sewage facilities, including septic systems, pump-out stations, holding tanks, and hauling systems Permitting Data for On-Site Sewage Facilities (Septic Systems) Annual data reports of types of on-site sewage facilities (OSSF) or septic systems installed by county and by year. Application forms are available online. What is the minimum lot size for a septic system in Clayton County, Georgia? The space required for a sewage system is determined by the suitability of the soils at the site, the number of bedrooms in the home, and the 100 foot set back from water wells. Development tax .$50.00 0000001409 00000 n The Board filed aCR-101 Preproposal Statement of Inquiry (PDF)to consider revisions to the chapter. 68-221-410. Ashland City, TN 37015(615) 792-4316. With Any accessory use or building located on a lot under this section shall conform with provisions of this resolution as related to use and dimensional requirements. Their work culminated with draft rules that the department presented at workshops held around the state. Hb```f`` |@Q$>qsRFY&92[&784MIEIN@c8)ee$$btLBCI#EC#V1J (f1[ |zw=&zA1Ho1q5f#A,FFz?0sJ ` HT endstream endobj 90 0 obj 232 endobj 55 0 obj << /Type /Page /Parent 48 0 R /Resources 56 0 R /Contents [ 63 0 R 71 0 R 73 0 R 75 0 R 77 0 R 83 0 R 85 0 R 87 0 R ] /MediaBox [ 0 0 612 792 ] /CropBox [ 0 0 612 792 ] /Rotate 0 >> endobj 56 0 obj << /ProcSet [ /PDF /Text ] /Font << /TT2 58 0 R /TT4 59 0 R /TT6 64 0 R /TT8 67 0 R /TT10 68 0 R /TT11 79 0 R >> /ExtGState << /GS1 88 0 R >> /ColorSpace << /Cs5 61 0 R >> >> endobj 57 0 obj << /Type /FontDescriptor /Ascent 1000 /CapHeight 734 /Descent -206 /Flags 32 /FontBBox [ -698 -207 1625 1065 ] /FontName /Tahoma-Bold /ItalicAngle 0 /StemV 182 >> endobj 58 0 obj << /Type /Font /Subtype /TrueType /FirstChar 32 /LastChar 150 /Widths [ 278 0 355 556 556 889 0 191 333 333 0 584 278 333 278 278 556 556 556 556 556 556 556 556 556 556 278 278 0 584 584 556 0 667 667 722 722 667 611 778 722 278 500 667 556 833 722 778 667 778 722 667 611 722 667 944 0 667 611 0 0 0 0 0 0 556 556 500 556 556 278 556 556 222 222 500 222 833 556 556 556 556 333 500 278 556 500 722 500 500 500 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 222 333 333 0 556 ] /Encoding /WinAnsiEncoding /BaseFont /Arial /FontDescriptor 60 0 R >> endobj 59 0 obj << /Type /Font /Subtype /TrueType /FirstChar 32 /LastChar 90 /Widths [ 293 0 0 0 0 0 0 0 454 454 0 0 0 431 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 685 0 667 757 615 0 0 764 483 0 0 572 893 771 770 657 0 726 633 612 739 675 0 0 0 623 ] /Encoding /WinAnsiEncoding /BaseFont /Tahoma-Bold /FontDescriptor 57 0 R >> endobj 60 0 obj << /Type /FontDescriptor /Ascent 905 /CapHeight 718 /Descent -211 /Flags 32 /FontBBox [ -665 -325 2028 1006 ] /FontName /Arial /ItalicAngle 0 /StemV 94 /XHeight 515 >> endobj 61 0 obj [ /CalRGB << /WhitePoint [ 0.9505 1 1.089 ] /Gamma [ 2.22221 2.22221 2.22221 ] /Matrix [ 0.4124 0.2126 0.0193 0.3576 0.71519 0.1192 0.1805 0.0722 0.9505 ] >> ] endobj 62 0 obj 578 endobj 63 0 obj << /Filter /FlateDecode /Length 62 0 R >> stream
Robert Hendricks Obituary, 5 Letter Words With Two O's Not Together, Articles M